Check Point Software Technologies Smart-1 150 Service Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
Customer Replaceable Parts
5. Make sure that the additional hard drives have been inserted correctly and are recognized by the system
by running the command
/sbin/raidconfig status
6. Stop all Check Point processes by running cpstop or mdsstop
7. Stop all other processes that are using /var/log. To see a list of these processes, run lsof
/var/log
8. Add the additional storage to the file system by running the command
/sbin/raidconfig extendstorage
In the event that the storage extension process fails:
1. Run the command
/opt/MegaRAID/MegaCli/MegaCli CfgForeign -Clear -a0
2. Repeat steps 5 to 8 above.
Verifying Hard Drive Extension
1. Run the /sbin/raidconfig status command to view the status of the hard disk drives. Additional
hard disk drives should appear configured in additional four discs’ RAID 10 arrays.
2. Run the lvdisplay /dev/vg_splat/lv_log command. The additional storage should appear
available under this logical volume.
Cooling Fans
The Smart-1 appliance contains three cooling fans. Each cooling fan operates independently of the other(s),
providing redundancy in the event of failure.
This section presents the procedures for removing and installing a fan unit. It is not necessary to power off
the appliance before adding or removing a fan unit.
Removing Fan Units
To remove a fan unit:
1. Loosen the retaining screws in the corners of the fan assembly.
2. Gently pull the fan unit out of the appliance.
Installing Fan Units
To install a fan unit:
1. Insert the fan unit into the appliance. Push firmly until it clicks into place.
2. Tighten the retaining screws in the corners of the fan assembly.
Page view 36